DESIGN OF WATER DISTRIBUTIONNETWORKUSING EPANET 2.2



EOI: 10.11242/viva-tech.01.05.001

Download Full Text here



Citation

Mr.Prof. Dr. Rajeev Kale, Mr. Shubham Zagade, Mr. Rahul Solanki, Rutuja Shinde, "Truss Optimization", VIVA-IJRI Volume 1, Issue 6, Article 4, pp. 1-6, 2023. Published by Computer Engineering Department, VIVA Institute of Technology, Virar, India.

Abstract

In India, due to rapid-fire growth of industrialization, there arise a need of storehouse and manufacturing of goods which can be fulfilled by proper designed artificial storehouse. This study gives an idea to carry out the design of an artificial storehouse. This content of work is decided as to know the different types of force/cargo goods to be considered while designing artificial storehouse with the help of literature review. This structure is proposed to design according to IS 8002007 and the dead, live, the wind cargo analysis is done according to IS.

Keywords

Auto Cad, Staad Pro, Warehouse, Dead load, Live Load, Wind Load, Load Combination

References

  1. M.Suneethal,Naresh Kumar, Gillela Reddy October 2016, "Design and Analysis of Industrial Building with Gable Roof by using STAAD.PRO" International Journal of Advance Technology In Engineering and Science
  2. Vaibhav B. Chavan, Vikas N. Nimbalkar And Abhishek P. Jaiswal, Vol. 3, Issue 2, February 2014 Economic Evaluation Of Open And Hollow Stuctural Sections In Industrial Trusses", Aci Structural Journal.
  3. C.M. Meera, June 2013 "Pre- Engineered Building Design of an Industrial warehouse". International Journal of Engineering Sciences and Emerging Technologies.
  4. Subhrakant Mohakul, Dr. Shaikh Yajdani, Abhay Dhurde, August 2014 "Design of industrial storage shed and analysis of stresses produced on failure of a joint". International Journal of Civil Engineering and Technology.
  5. Manan D.Maisuri, Hitesh K.Dhameliya, Hiten L.Kheni, Vol.1 Issue 12, December 2013, "Review Of Comparison Between Conventional Steel And Tubular Steel Section For Multi Span Industrial Shed With Truss And Portal Frame" International Journal of Advance Engineering and Research Development.
  6. Shaiv Parikh,"Design of Steel Compression Members" (According To IS: 800)
  7. Yash Patel, Shreepalsinh Gohil, Dr Tausif Kauswala,Het Parmar, volume 3 issue 10, april2006, "Analysis And Design Of Conventional Industrial Roof Truss, And Compare It With Tubular Industrial Roof Truss" International Journal of Science Technology and Engineering.
  8. A.Jayaraman, R Geethamani, N Sathyakumar,N Karthiga Shenbagam,"Design and Economical of Roof Trusses & Purlins (comparison of LSM and WSM)"
  9. Design of Steel Structures by N. Subramanian
  10. IS: 800-2007:- General Construction In Steel - Code of Practice.
  11. IS: 875 (Part 1) 1987:- Code of Practice for Design Loads for Buildings and Structures- Dead Loads.
  12. IS: 875 (Part 2) 1987:- Code of Practice for Design Loads for Buildings And Structures- Live Loads.
  13. IS: 875 (Part 3) 1987:- Code of Practice for Design Loads for Buildings And Structures- Wind Loads.
  14. Is 800:2007 "Indian standard Code of Practice for General Construction in Steel Bureau of Indian Standards" Third Revision, New Delhi, India.
  15. IS: 801-1975 (Reaffirmed 1995) "Indian standard Code of practice for use of Cold Formed light gauge Steel Structure Member in General Building Construction" Bureau of Indian standard, First Revision, New Delhi, India.
  16. Arunkumar pattar & Sunil kumar chavan (2015)-"Analysis and Design of Multi Storied Structural System with Wind Load Effects Using Staad Pro", international journal of innovative research in technology".