ANALYSIS & DESIGN OF A COMMERCIAL BUILDING BY USING E-TAB SOFTWARE



EOI: 10.11242/viva-tech.01.05.018

Download Full Text here



Citation

Yadnyesh Vaiti, kritesh Patil, Satish Yadav, Bhargav Nijai, "ANALYSIS & DESIGN OF A COMMERCIAL BUILDING BY USING E-TAB SOFTWARE", VIVA-IJRI Volume 1, Issue 6, Article 18, pp. 1-5, 2023. Published by Computer Engineering Department, VIVA Institute of Technology, Virar, India.

Abstract

Marketable structures have come a part of the day to day développent. By that the construction of the marketable structure gained significance, their system of Constructions also gained significance. The design not only requires imaginations but also good external reg with experience and judgement. The applicable Indian standard canons are used for design and analysis of crossbeams, shafts, columns, footings. This design describes a system of Analysis and Design of Multistoried marketable structure. The compass Behind presenting this design is to learn the conception of Construction, and to Design an elegant, safe and durable structure with frugality. The most prominent & accessible system of designing and assaying Multistoried marketable structure in ETABS.ETABS, models may be really rendered, and all results can be shown directly on the structure. ETABS provides unrivaled suite of tools for structural masterminds designing structures, whether they are working on one story artificial structures or the Altitudinous marketable High rises. The total modelling of the structure is done by ETABS.

Keywords

ETAB software, IS Code book.

References

  1. Design of R.C.C. Structures by N. Krishna Raju
  2. KunkunTu, Xiaoqing Wang, Lizhuo Kong, Huanjun Chang, JunliangLiu,“Fabrication of robust, damage-tolerant superhydrophobic coatings on naturally micro-grooved wood surfaces”,RSC Advanced manuscript
  3. IS: 456-2000, Code of Practice Plain and Reinforced concrete.
  4. IS: 875-1987 (Part 1) – 1987, Code of Practice for Design Loads (other than earthquake) for buildings and structures
  5. IS: 875-1987 (Part 2) – 1987, Code of Practice for Design Loads (other than earthquake) for buildings and structures - Imposed loads
  6. Mohd atif, Prof. Laxmikant vairagade, Vikrant nair, “comparative study on seismic analysis of multistorey building stiffened with bracing and shear wall”, IRJET-2015
  7. J Nabin Raj , S.Elavenil, “Analytical Study on Seismic Performance of Hybrid Structural System Subjected To Earthquake” , IJMER-2012
  8. Sonia Longiam, S Aravindan, “Analysis and design of shopping mall against lateral forces”. International journal of engineering science invention
  9. SP16, Bureau of Indian standard, New Delhi, 1990.
  10. Syed khasim mutwalli, Dr. Shaik kamal mohammed azam, “Dynamic response of high rise structure under the influence of shear walls”. Syed khasim mutwalli. Int. journal of engineering research and applications. ISSN:22248-9622, Vol 4.
  11. Mahesh N. Patil, Yogesh N. Sonawane, “Seismic Analysis of Multi-storied Building”, International Journal of Engineering and Innovative Technology, ISSN: 2277-3754, Volume 4, Issue 9, March 2015
  12. Design and analysis of multi-storeyed building under static and dynamic loading conditions by using E-TABS by Balaji and Selvarasan in International Journal of Technical Research and Applications, Volume 4 , Issue 4(July-Aug, 2016),