COMPARATIVE ANALYSIS OF G+10 BUILDINGS WITH AND WITHOUT SHEAR WALLS USING ETABS
EOI: 10.11242/viva-tech.01.08.002
Citation
Sameer Gurav,Prajyot Tharali, Abhijit Shikpule , " COMPARATIVE ANALYSIS OF G+10 BUILDINGS WITH AND WITHOUT SHEAR WALLS USING ETABS. ", VIVA-IJRI Volume 1, Issue 8, Article 2, pp. 1-4, 2025. Published by Computer Engineering Department, VIVA Institute of Technology, Virar, India.
Abstract
This study conducts a comparative analysis of G+10 buildings, examining the structural performance of models with and without shear walls. Utilizing ETABS software, we investigate how the presence and strategic placement of shear walls influence key structural parameters, including lateral load resistance, deflection, and overall stability. The analysis encompasses various configurations of shear wall locations centralized, distributed, and corner placements to determine their effects on the building’s performance under seismic loading conditions. Results indicate that shear walls significantly enhance structural integrity and reduce lateral displacements, with optimal configurations yielding the best performance outcomes. This research provides valuable insights for architects and engineers in designing resilient structures that can effectively withstand dynamic forces. Shear walls are added to the building interior to provide more strength and stiffness to the building when the exterior walls cannot provide sufficient strength and stiffness. It is necessary to provide these shear walls when the tolerable span- width ratio for the floor or roof diaphragm is exceeded. The present work deals with a study on the improvement location of shear walls in symmetrical high-rise building. Position of shear walls in symmetrical buildings has due considerations..
Keywords
ETABS software, Shear walls, improvement location of shear walls, with & without shear wall.
References
- Dinesh Kumar, Mr. Nandeswar Lata, Dr. Bharat Nagar: Importance of shear wall in multi-story building with seismic analysis using etabs, Volume: 07 Issue: 07 | July 2020.
- Sandeep Gupta, Dr. Saleem Akhtar, Mr. Aslam Hussain: Effect of Shear Wall Location on Bending Moment and Shear Force of Multistory Building Subjected to Earthquake Loading International Journal of Computer and Advanced Engineering Research (IJCAER) Volume III– Issue II, March 2016.
- AshishS.Agrawal, S.D.Charkha: Effect of change in shear wall location on storey drift of multistorey building subjected to lateral loads, International Journal of Engineering Research and Applications (IJERA) Vol. 2, Issue 3, May Jun 2012.
- R.S.Mishra, V.Kushwaha, S.Kumar: A Comparative Study of Different Configuration of Shear Wall Location in Soft Story Building Subjected to Seismic Load, International Research Journal of Engineering and Technology (IRJET) Volume: 02 Issue: 07 | Oct-2015.
- Youssef I. Agag , Mohamed E. El Madawy , Raghda I. Halima (2014): The Effect of Shear Walls Positions and Dimensions Variation on the Analysis of Multi-Story Building, International Journal of Scientific Engineering and Research (IJSER)